百姓快3

Company main products: pump valve    Tel:0550-7031888
RSS|Shopping Cart|Mobile Version|Chinese|English
ANHUI TIANMA PUMP VALVE GROUP CO.,LTD OF CHINA
免費服務熱線

400-889-9558

13605505188 、18098329999

Popular Keywords:
Contact / Contact
  • ANHUI TIANMA PUMP VALVE GROUP CO.,LTD OF CHINA
  • Tel:0550-7031888
  • Fax:0550-7321688
  • Email:sales@ahtmbv.com
  • Address:NO. 1 TIANMA ROAD ECNOMIC DEVELOPMENT ZONE OF TIANCHANG, ANHUI, CHINA
Tianma valve - submersible pump fault phenomenon and trouble

Fault phenomenon and elimination method of submersible pump
Submersible pumps do not have water, indirect water or a lack of water
1, check the motor. To see whether the motor has been started, not starting, check the motor circuit, circuit fault can be excluded; see the motor circuit is connected to the correct, check whether the pump reverse, reverse the pump, the power supply line can be changed.
2, check the pipeline. To see whether there is blocking, pipeline rupture, strainer is blocked. If the pipeline rupture should be repair welding or tube, remove the blockage, the fault can be ruled out.
3, check the pump casing seal, check the impeller is damaged. Elimination method: the replacement of Xinmi sealing ring, impeller.
Two, the motor can not start and with the hum
1, check the motor circuit, whether a phase circuit, check voltage, whether the voltage is too low. Circuit repair, adjust the voltage is normal, the fault can be ruled out.
2, check whether there is a foreign body inside the impeller, bearing damage, remove foreign matter or replace the bearing can be.
Three, the current is too large, the current table pointer swing
1, buy a new pump, the reasons for the shaft bending, the bearing is not concentric, immediately return the sales department or manufacturer.
2, check whether the thrust bearing wear is serious, whether the impeller and seal ring friction marks. The elimination method, the replacement thrust bearing or the thrust disc, the impeller rotation is no longer with the seal ring friction can.
3, check the shaft and the relative rotation is flexible, rotation is not flexible, should replace or repair the bearing.
4, water level dropped to below the water inlet. Flow or well change should be reduced.
Four, the unit running violent vibration
1, check the connection bolt is loose, should tighten the bolt.
2, the motor rotor imbalance, pump impeller imbalance, motor or pump shaft bending, etc., should be sent to the manufacturing plant for processing.

Return To The Top
  • ANHUI TIANMA PUMP VALVE GROUP CO.,LTD OF CHINA  Copyright ? 2015      
  • Tel:0550-7031888  Fax:0550-7321688  Email:sales@ahtmbv.com
  • Address:NO. 1 TIANMA ROAD ECNOMIC DEVELOPMENT ZONE OF TIANCHANG, ANHUI, CHINA
网信快3-专业购彩 购彩快3-互动百科 彩神快3-安全购彩 在线快3-百姓快3 购彩之家-互动百科 凤凰快三-手机版 幸运快3-安全购彩